技术数据
A端
Head A: Connection
  • M12
Head A: Angle cable outlet
Head A: Gender
Head A: Coding
  • A
Head A: No. of poles
  • 5
Head A: LED
Head A: Width across flats
  • AF14
Head A: Tightening torque
  • 0,6 Nm
Head A: Knurled nut material
  • 不锈钢 (V4A)
Head A: Body color
  • 蓝色
Labeling sleeve side A
B端
Head B: Connection
  • M12
Head B: Angle cable outlet
  • 90°
Head B: Gender
  • 母头
Head B: Coding
  • A
Head B: No. of poles
  • 5
Head B: LED
Head B: Width across flats
  • AF14
Head B: Knurled nut material
  • 不锈钢 (V4A)
Head B: Body color
  • 蓝色
Head B: Gasket material
  • EPDM
Labeling sleeve side B
电缆
Cable length
  • 500 cm
Shielded
AWG
  • 22
External sheath: Material
  • TPE-S
External sheath: Color
  • 蓝色
Wire cross section
  • 0.34 mm²
Shielded
Cable length
  • 500 cm
AWG
  • 22
Torsion speed
  • 最高35次/分钟
Conductor: Material
  • 裸铜
External sheath: Material
  • TPE-S
Insulation: Material
  • PP
Paired stranding
Torsion stress in °
  • ±180 °/m
Total stranding
  • 5芯绞线围绕中心填充线
Wire cross section
  • 0.34 mm²
Wire processing
External sheath: Color
  • 蓝色
机械参数
Head A: Degree of protection
  • IP65, IP68, IP69K
Head B: Degree of protection
  • IP65, IP68, IP69K
Torsion speed
  • 最高35次/分钟
Torsion stress in °
  • ±180 °/m
环境条件
Dragchain capable
Head A: Chemical resistance
  • 耐化学腐蚀性符合ECOLAB测试要求。如果使用其他介质,必须根据具体应用测试材料的耐化学腐蚀性。
Head A: Flame resistance
  • HB (UL 94)
Head A: Oil resistance
  • Good resistance to ASTM 1 oil and mineral oils. Limited resistance to hydraulic oils. If other oils are used, the resistance must be checked in relation to the application.
Head A: Acid and alkali resistant
  • Chemical resistance tested according to ECOLAB. If other media are used, the material resistance must be tested according to the application.
Head A: Pollution degree
  • 3
Head B: Chemical resistance
  • 耐化学腐蚀性符合ECOLAB测试要求。如果使用其他介质,必须根据具体应用测试材料的耐化学腐蚀性。
Head B: Flame restistance
  • HB (UL 94)
Head B: Oil resistance
  • Good resistance to ASTM 1 oil and mineral oils. Limited resistance to hydraulic oils. If other oils are used, the resistance must be checked in relation to the application.
Head B: Acid and alkali resistant
  • Chemical resistance tested according to ECOLAB. If other media are used, the material resistance must be tested according to the application.
Head B: Pollution degree
  • 3
Cable: Acid and alkali resistant
  • Good (analogue FDA 21 178.3620, 178.3297, 177.1520)
Cable: Silicone-free
商业数据
Eclass
  • 27060311

下载
数据表

回到顶部